Skip to content
Sujay Fire LLP

Fire Fighting System

Fire Hydrant System

High-Volume Water Supply for Manual Firefighting Operations

A fire hydrant system is a dedicated pressurised water distribution network — consisting of underground/overhead tanks, pumps, rising mains, landing valves, and hose reels — that gives firefighters immediate access to high-volume water supply anywhere in the building.

  • Expert Installation
  • AMC & Servicing
  • Across Maharashtra
Fire Hydrant System — Sujay Fire LLP, Pune, Maharashtra

Category

Fire Fighting System

Key Features

NBC, UDCPR, IS Code

Every system sized and routed per National Building Code guidelines

Internal & External Hydrants

Covers both internal landing valves on each floor and external yard hydrants for fire brigade access

Stainless Steel Pipework

Schedule 40 MS pipes with epoxy coating or SS option for corrosion-resistant distribution

Commissioning & Testing

Full hydraulic testing and fire pump commissioning with documented performance report

Ideal For

High-Rise Residential BuildingsCommercial ComplexesIndustrial PlantsHotelsHospitalsAirports

Engineered to Code

Hydrant System Design by Building Height

Every building category demands a different hydrant configuration. Here's how we design each one to meet NBC norms and pass fire-NOC inspection.

Below 24 m — Down Comer Fire Hydrant — Sujay Fire LLP, Pune
01

Below 24 m — Down Comer Fire Hydrant

Downcomer fire fighting systems are provided in residential buildings above 15 metre height — this category comprises P+5, P+6, and P+7 structures. The fire department recommends a booster fire pump with a vertical riser and basic equipment on each floor.

24 m to 45 m — Wet Riser Fire Hydrant — Sujay Fire LLP, Pune
02

24 m to 45 m — Wet Riser Fire Hydrant

These residential buildings are provided with a wet riser, courtyard fire hydrant, and manual fire alarm system.

A main pump and standby pump are provided at the underground water tank. If a sprinkler system is provided to the basement / multi-level parking, a jockey pump is also installed. A booster pump is provided at the terrace.

45 m to 60 m — Fire Hydrant System — Sujay Fire LLP, Pune
03

45 m to 60 m — Fire Hydrant System

These residential buildings are provided with a wet riser, are fully sprinklered, and have an addressable detection system.

Hydrant pump, sprinkler pump, standby pump, and jockey pump are provided at the underground water tank. A booster pump is provided at the terrace.

Staircase, lobby, and lift pressurization is included.

This system can be integrated with other services like lift, generator, boom barrier, access control, and SMS alert system.

Above 60 m — Sujay Fire LLP, Pune
04

Above 60 m

These residential buildings are provided with multiple wet risers, are fully sprinklered, and have an addressable detection system.

A multi-stage multi-outlet hydrant pump, sprinkler pump, standby pump, and jockey pump are provided at the underground water tank. A booster pump is provided at the terrace.

Staircase, lobby, and lift pressurization is included.

This system can be integrated with other services like lift, generator, boom barrier, access control, and SMS alert system.

Courtyard Fire Hydrant — Sujay Fire LLP, Pune
05

Courtyard Fire Hydrant

The courtyard fire hydrant system is installed to fight fire from outside the building. The hydrant valves are installed along with a hose box, hose pipe, and nozzle at every 30/45 metre interval depending on the category of hazard.

2000+
Buildings Secured
100%
NOC Success Rate
20+
Years in Pune

Other Fire Fighting System

Get Fire Hydrant System for Your Building

Our Pune-based engineers will assess your requirements and provide a detailed quote.