Aspirating smoke detection, gas fire suppression and clean agent extinguishers for data centres and server rooms — protecting assets without water damage.

Detection, suppression and containment systems we supply and install for data centres and server rooms.
Actively draws air samples through a pipe network to a highly sensitive laser detection chamber — detecting fire at the incipient stage, sometimes hours before conventional detectors respond.
Smoke, heat, multi-sensor and beam detectors selected for each room's hazard profile — for fast response with minimal false alarms.
Total flooding systems discharge clean agent (FK-5-1-12, CO2 or Novec 1230) throughout an enclosed space, activating within seconds of detection and protecting assets without water damage.
Wet pipe sprinklers for standard areas; pre-action systems for data centres and sensitive storage.
Non-conductive, residue-free extinguishers for servers, electrical panels and precision equipment — no cleanup and no damage to electronics.
Fire-rated doors contain fire and smoke within a compartment. Tested and certified to IS 3614, in 30, 60, 90 and 120-minute ratings.
The right agent selected for each space based on asset value, room volume, and whether the space is occupied.
We design, supply, install and commission gas-based and agent-based suppression systems.
Coordination for approvals from Fire Authorities across Pune, Pimpri-Chinchwad, PMRDA and MIDC offices.
Periodic maintenance, documented service reports, Form B certification and 24/7 priority emergency call-out.
Our AMC covers fire alarm, detection and suppression systems, with documented service reports, Form B certification and 24/7 priority emergency call-out.
Gas fire suppression systems discharge clean agent throughout the enclosed space and protect assets without water damage. Where sprinklers are used, pre-action systems are suited to data centres and sensitive storage.
CO2 flooding, FK-5-1-12, NAFS 125, Inergen, electric panel suppression and DSPA systems. The agent is selected based on asset value, room volume, and whether the space is occupied.
Yes. Our suppression systems include an alarm and abort panel with a pre-discharge alarm and a 30-second abort delay for safe evacuation before gas release.
Aspirating Smoke Detection (ASD) systems — including VESDA and similar technologies — actively draw air samples through a pipe network to a highly sensitive laser detection chamber. They can detect fire at the incipient stage, sometimes hours before conventional detectors respond.
Yes. Our AMC covers fire suppression (CO₂ / FM-200 / clean agent) systems — cylinder weight and charge checks, leak and pressure testing, control panel and actuator checks, and nozzle and piping inspection — with documented service reports.